Industrial UPS system offering a full-IGBT innovative design. A wide range of possible options
Key advantages
Safety | Bidirectional rectifier to perform battery deep discharging |
Smart access to UPS data | Large color LCD touch-pad for user interface |
USB access | Export of all the recorded events using USB flash drive. |
Best-in-class performance to optimize expenses | Reduced CAPEX – Upstream transformer, switchgear and cables are downsized thanks to high input power factor, low THDi rejection and low inrush current Proven digital Vector Control technology to control the output waveform, even on non linear loads |
Controlled OPEX : | Lower power consumption thanks to high efficiency |
Industrial-grade maintainability | Innovative design allowing an easy front access to all components Removable ID Cards which safeguard the UPS parameters and facilitate control board replacement Configurable active mimic diagram |
Industrial flexibility | Fit-for-purpose battery selection Galvanic isolation: either output and/or input transformers Wide range of electrical and mechanical options |
Input
Input voltage | 1-ph x 230 Vac (220, 240) 3-ph+N x 400 Vac (380, 415) ± 10 % (other voltages and tolerances on request) |
Inrush current | ≤ 1 In (without input transformer) ≤ 8 In (with input transformer) |
Power factor | Up to 0.98 |
Frequency range | 50 Hz (60 Hz factory setting) ± 5 % |
Embedded input features | AC input isolator switch Surge protection with MOV lightning arrestors |
Output
110 Vdc | 5 – 10 – 20 (1 or 3 ph) |
220 Vdc | 10…60 (1 or 3 ph) |
400 Vdc | 40…250 (3ph only) |
Intermediate DC Circuit
Nominal DC Voltage | 110 / 220 / 400 Vdc |
Voltage stability in steady state | ≤ 1 % in float mode (input within tolerance) |
Voltage ripple | ≤ 1 % RMS (with and without battery connected) |
Current limitation | I nominal |
Charging characteristic | IU according to DIN 41773 |
Output
AC voltage | 1-ph: 230 Vac (208, 220, 240) ; 110 Vac (115, 120, 127) 3-ph: 400 Vac (380, 415) ; 208 Vac (190, 200, 220) |
Frequency stability | With internal oscillator ± 0.1 % With reserve synchronism ± 1 % (1 to 4 % adjustable) |
Voltage stability(0-100% load variation) | Static ± 1 %Dynamic VFI SS 111 as per IEC62040-3, class 1 |
Overload inverter(in % of nominal power) | 150 %/1 min – 125 %/10 min at nominal output voltage |
Short-circuit clearance(in % of nominal current) | 1-ph and 3-ph: 250 %/100 ms – 150 %/5 s |
Voltage distorsion | With 100 % linear load < 2 % With 100 % non linear load < 5 % as per IEC62040-3 |
Allowable power factor | 0.5 lagging to 0.5 leading |
Allowable crest factor | 3/1 |
Embedded output features | Output switch • Output isolation transformer class H |
Reserve line
Embedded reserve line features | Integrated manual bypass switch Inbuilt input reserve line switch |
Battery
arrestorsBatteryType | Lead acid or nickel cadmium, vented or recombination |
Battery current limitation | 0.1 C (Lead Acid) / 0.2 C (Nickel Cadmium) |
Embedded battery features | Inbuilt battery circuit breaker with aux. contact Battery reverse polarity protection and indication Battery Low Voltage Disconnection (LVD) Battery test, automatic or manual mode Battery room temperature sensor for battery charge compensation |
General data
Efficiency | Up to 92 % (according to rating and config.) |
Operating temperature | From 0 to 40 °C (without system derating) |
T°C operating / Storage | 0…40 °C without derat. syst. / -20…70 °C battery excluded |
Relative humidity | < 95 % non condensing at 20 °C |
Operating altitude | 1000 m (without system derating) |
Cooling | Fan assisted |
Ingress protection | Internal IP20 – external IP42 |
Noise (at 1m in front of the unit) | 62 to 72 dB (according to rating) |
Input/output isolation | 2500 VAC / 1 minute |
Feet | 100 mm height with feet cover |
Gland plate | Aluminium non-magnetic, 3 mm thickness |
Dimensions & colour | From 1 x 800 mm to 2 x 1200 mm width / RAL 7035 |
Embedded system features | Internal cabinet lighting / Lifting Eyes Auxiliary power socket Display language: EN, FR, SP, RU, TR (factory setting) |
Options
Rectifier | Input isolation transformer Special 1-ph or 3-ph input voltage (up to 3 x 690 Vac) Input voltage tolerance from – 20 % to + 15 % Input circuit breaker with aux. contact and breaking capacity up to 70 kA Automatic reverse phase sequence correction Automatic input phase failure adaptation |
Battery | Protection box (circuit breaker), black start, automatic or manual mode ; DC earth fault detection |
Output | Circuit breaker with aux. contact Emergency Power Off |
Reserve | Circuit breaker with aux contact Reserve isolation transformer (H class) Reserve voltage stabilizer (servo-controlled) Stabilizer output isolator |
System | Parallel configuration (distributed parallel) Operating temperature up to 50 °C with derating Operating altitude up to 3000 m with derating Redundant monitored fans G3 conformal coating on elec. cards against dust, humidity / Halogen free cabling Space heater with thermostat or hygrostat |
Mechanical | Top cable entry – Antivibration pads Special frame color (RAL paint standards) Special feet height 200 mm or base frame |
Communication | Additional volt-free contacts (up to 20 relays) Modbus RTU (RS232 or RS485) ; TCP-IP / Profibus / SNMP PPVIS monitoring software |
Standards
IEC/EN 62040-1: 2008 IEC/EN 62040-2: 2006 IEC/EN 62040-3: 2011 IEC/EN 60950-1: 2013 AMD2: 2014 |